{"id":2893,"date":"2020-11-22T09:00:06","date_gmt":"2020-11-22T17:00:06","guid":{"rendered":"https:\/\/www.linquip.com\/blog\/?p=2893"},"modified":"2025-08-28T01:12:21","modified_gmt":"2025-08-28T09:12:21","slug":"tnc-earthing-system","status":"publish","type":"post","link":"https:\/\/www.linquip.com\/blog\/tnc-earthing-system\/","title":{"rendered":"TNC Earthing System\u0589 A Detailed Explanation"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.linquip.com\/blog\/tnc-earthing-system\/#TNC_earthing_system_characteristics\" >TNC earthing system characteristics<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.linquip.com\/blog\/tnc-earthing-system\/#TNC_earthing_system_diagram\" >TNC earthing system diagram<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.linquip.com\/blog\/tnc-earthing-system\/#What_does_TNC_stand_for\" >What does TNC stand for?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.linquip.com\/blog\/tnc-earthing-system\/#Advantages_of_the_TNC_Earthing_System\" >Advantages of the TNC Earthing System<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.linquip.com\/blog\/tnc-earthing-system\/#Disadvantages_of_the_TNC_Earthing_System\" >Disadvantages of the TNC Earthing System<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.linquip.com\/blog\/tnc-earthing-system\/#Download_TNC_Earthing_System_PDF\" >Download TNC Earthing System PDF<\/a><\/li><\/ul><\/nav><\/div>\n<p><span style=\"font-weight: 400;\">The earthing of an electricity supply network requires its network plant and customer electrical equipment to be connected to earth to promote safety and reduce the possibility of damage to equipment. Effective earthing prevents long-term over voltages and minimizes the risk of electric shock hazards. Earthing also provides a predetermined path for earth leakage currents, which find use in disconnecting the faulty plant or circuit by operating the protective devices.<\/span><\/p>\n<p>With distributed earth electrodes spaced as consistently as feasible, the TN-C system requires an effective equipotential environment within the installation. When employing electric items, the <a href=\"https:\/\/www.linquip.com\/equipment?q=Earthing%20System\"><strong>TNC Earthing System<\/strong><\/a> is critical. TNC Earthing Systems are available from a variety of <a href=\"https:\/\/www.linquip.com\/suppliers-companies?q=earthing-system\"><strong>Suppliers and Companies<\/strong><\/a>, as well as other manufacturers and distributors, and there are several Earthing Systems for sale on Linquip.<\/p>\n<p>A full list of Earthing System services is available on the Linquip website, which covers all OEM fleets. Linquip suppliers can assist you with this. Please contact TNC <a href=\"https:\/\/www.linquip.com\/experts?q=earthing-system\"><strong>Earthing System Experts<\/strong><\/a> in Linquip to learn more about how to connect with a diverse group of service providers who consistently deliver high-quality products.<\/p>\n<p><span style=\"font-weight: 400;\"> In this article, we will discuss the <\/span><span style=\"font-weight: 400;\">TNC earthing system<\/span><span style=\"font-weight: 400;\"> method. Read this new blog in Linquip to find out more about these <\/span><span style=\"font-weight: 400;\">types of <strong><a href=\"https:\/\/en.wikipedia.org\/wiki\/Earthing_system#:~:text=An%20earthing%20system%20(UK)%20or,for%20safety%20and%20functional%20purposes.&amp;text=In%20addition%20to%20electric%20power,grounding%20for%20safety%20or%20function.\" target=\"_blank\" rel=\"noopener noreferrer\">earthing systems<\/a><\/strong><\/span><strong>.<\/strong><\/p>\n<h2><span class=\"ez-toc-section\" id=\"TNC_earthing_system_characteristics\"><\/span><strong>TNC earthing system characteristics<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">The neutral conductor is also used as a protective conductor and is referred to as a PEN (Protective Earth and Neutral) conductor. This system is not permitted for conductors of less than 10 mm2 or portable equipment.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The <\/span><span style=\"font-weight: 400;\">TN-C system<\/span><span style=\"font-weight: 400;\"> requires an effective equipotential environment within the installation with dispersed earth electrodes spaced as regularly as possible. It is because the PEN conductor is both the neutral conductor and at the same time carries phase unbalance currents as well as third-order harmonic currents (and their multiples). The PEN conductor must therefore be connected to several earth electrodes in the installation.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">In the TNC system, the protective conductor function has priority over the neutral function, and<\/span><span style=\"font-weight: 400;\"> in particular, a PEN conductor must always be connected to the earthing terminal of a load. A jumper is also used to connect this terminal to the neutral terminal.<\/span><\/p>\n<h2><span class=\"ez-toc-section\" id=\"TNC_earthing_system_diagram\"><\/span><strong>TNC earthing system diagram<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">In TNC earthing method Neutral and protective functions are combined in a single conductor throughout the system. (PEN\u2014Protective Earthed Neutral).<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The supply source is directly connected to the earth and all exposed conductive parts of an installation are connected to the PEN conductor.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The system is shown diagrammatically in the figure below.<\/span><\/p>\n<p><img decoding=\"async\" class=\"size-full wp-image-2895 aligncenter\" src=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2020\/11\/Fig-2-TN-C-System-768x464-1.jpg\" alt=\"TNC earthing system - Linquip\" width=\"700\" height=\"422\" title=\"\" srcset=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2020\/11\/Fig-2-TN-C-System-768x464-1.jpg 700w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2020\/11\/Fig-2-TN-C-System-768x464-1-300x181.jpg 300w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2020\/11\/Fig-2-TN-C-System-768x464-1-696x420.jpg 696w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2020\/11\/Fig-2-TN-C-System-768x464-1-697x420.jpg 697w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/><\/p>\n<h2><span class=\"ez-toc-section\" id=\"What_does_TNC_stand_for\"><\/span><strong>What does TNC stand for?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">In the symbol of the power supply method stipulated by the International Electrotechnical Commission (IEC), the first letter represents the relationship between the power system and the ground. For example, <\/span><b>T <\/b><span style=\"font-weight: 400;\">indicates that the neutral point is directly grounded<\/span><span style=\"font-weight: 400;\">.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The second letter indicates the electrically conductive device exposed to the ground. For example, <\/span><b>N <\/b><span style=\"font-weight: 400;\">means that the load is protected by zero.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The third letter indicates the combination of working zero and protective line. For example, <\/span><b>C<\/b><span style=\"font-weight: 400;\"> indicates that the working neutral line and the protection line are one, such as <\/span><span style=\"font-weight: 400;\">TNC earthing system<\/span><span style=\"font-weight: 400;\">. <\/span><b>S<\/b><span style=\"font-weight: 400;\"> indicates that the working neutral line and the protection line are strictly separated, so the PE line is called a dedicated protection line, such as <\/span><span style=\"font-weight: 400;\">TNS earthing arrangement<\/span><span style=\"font-weight: 400;\">.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Therefore, in <\/span><span style=\"font-weight: 400;\">TN-C (Terra Neutral \u2013 Combined) method<\/span><span style=\"font-weight: 400;\">,<\/span><span style=\"font-weight: 400;\"> earth<\/span><span style=\"font-weight: 400;\">,<\/span><span style=\"font-weight: 400;\"> and neutral share the same conductor (two-wire single-phase).<\/span><\/p>\n<p>For those looking to delegate their academic work, consider reaching out to <a href=\"https:\/\/writepaper.com\/\" target=\"_blank\" rel=\"noreferrer noopener\">write a research paper for me at WritePaper<\/a>.<\/p>\n<h3><strong>What&#8217;s The Difference Between PME And TNCS?<\/strong><\/h3>\n<p>The combined earth\/neutral conductor is linked to the ground in several locations along with the supply network, either buried underground or at the poles for overhead supplies. Because of the multiple earthing, a TNCS supply is commonly referred to as a PME supply (Protective Multiple Earthing).<\/p>\n<h3><strong>Are TNCs Always PME?<\/strong><\/h3>\n<p>It certainly does. Not all TN-C-S supplies are PME, and not all PME supplies are TN-C-S. Without the multiple earthing, you may get a TN-C-S supply directly from an on-site transformer.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Advantages_of_the_TNC_Earthing_System\"><\/span><strong>Advantages of the TNC Earthing System<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Here are some of the advantages of the TNC earthing method.<\/strong><\/p>\n<ul>\n<li style=\"font-weight: 400;\">The TNC earthing system always provides a return path for faults in the low voltage grid. The grounding conductors at the transformer and all customers are interconnected. This ensures a distributed grounding and reduces the risk of a customer not having a safe grounding.<\/li>\n<li style=\"font-weight: 400;\">There is no overvoltage stress on equipment insulation.<\/li>\n<li style=\"font-weight: 400;\">TNC system could work with simple over current protection.<\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">The low cost is the main advantage of using the TNC earthing method. Especially the PE conductor cost has the least cost among other earthing methods.<\/span><\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-2897\" src=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2020\/11\/tn-c-system-l-e1604483465813.jpg\" alt=\"TNC earthing system - Linquip\" width=\"700\" height=\"413\" title=\"\" srcset=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2020\/11\/tn-c-system-l-e1604483465813.jpg 1024w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2020\/11\/tn-c-system-l-e1604483465813-300x177.jpg 300w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2020\/11\/tn-c-system-l-e1604483465813-768x453.jpg 768w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2020\/11\/tn-c-system-l-e1604483465813-696x411.jpg 696w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2020\/11\/tn-c-system-l-e1604483465813-712x420.jpg 712w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Disadvantages_of_the_TNC_Earthing_System\"><\/span>Disadvantages of the TNC Earthing System<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>The disadvantages of the TNC system are as follows.<\/strong><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Faults in the electrical network at a higher voltage level may migrate into the low voltage grid grounding causing touch voltages at low voltage customers.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">A fault in the low voltage network may cause touch voltages at other low voltage customers.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">The potential risk of exposed conductive parts with the neutral conductor in the event of a break-down of the neutral network conductor as well as for low voltage network phase to neutral and phase to ground faults and medium voltage to low voltage faults.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">TN-C system is less effective for Electromagnetic Compatibility (EMC) problems.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">TNC earthing method is the least safe one among earthing methods.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">This type of earthing is not commonly used in some countries due to the risks associated with fire in hazardous environments and due to the presence of harmonic currents making it unsuitable for electronic equipment.<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><span style=\"font-weight: 400;\">So, there you have a detailed description of the <\/span><span style=\"font-weight: 400;\">TNC earthing system<\/span><span style=\"font-weight: 400;\">. If you have any experience with other types of earthing method, let us know by leaving a reply in the comment section. Is there any question we can help you through? Feel free to <a href=\"https:\/\/www.linquip.com\/sign-up?client_redirect=\/\" target=\"_blank\" rel=\"noopener noreferrer\">sign up on Linquip<\/a> to get the most professional advice from our experts.<\/span><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Download_TNC_Earthing_System_PDF\"><\/span><strong>Download TNC Earthing System PDF<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"su-button-center\"><a href=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2020\/11\/linquip.com-TNC-Earthing-System-A-Detailed-Explanation.pdf\" class=\"su-button su-button-style-default su-button-wide\" style=\"color:#FFFFFF;background-color:#2D89EF;border-color:#246ec0;border-radius:12px\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"color:#FFFFFF;padding:0px 30px;font-size:22px;line-height:44px;border-color:#6cadf4;border-radius:12px;text-shadow:none\"> Download PDF<\/span><\/a><\/div>\n<h3><b>Buy Equipment or Ask for a Service<\/b><\/h3>\n<p>By using Linquip RFQ Service, you can expect\u00a0to receive quotations from various suppliers across multiple industries and regions.<\/p>\n<p style=\"text-align: center;\"><strong><a href=\"http:\/\/linquip.com\/get-quote?utm_source=blog&amp;utm_medium=content&amp;utm_campaign=product_list&amp;utm_term=product_list&amp;utm_content=rfq\" target=\"_blank\" rel=\"noopener\">Click Here to Request a Quotation From Suppliers and Service Providers<\/a><\/strong><\/p>\n<p><em><strong>Read More In Linquip<\/strong><\/em><\/p>\n<ul>\n<li><span style=\"font-size: 10pt; font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><a href=\"https:\/\/www.linquip.com\/blog\/earthing-system\/\" target=\"_blank\" rel=\"noopener\">Earthing System: A Simple Explanation about Grounding System<\/a><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-size: 10pt; font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><a href=\"https:\/\/www.linquip.com\/blog\/it-earthing-system\/\" target=\"_blank\" rel=\"noopener\">IT Earthing System: The Key and Essential Facts Everybody Wants to Know<\/a><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-size: 10pt; font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><a href=\"https:\/\/www.linquip.com\/blog\/types-of-temperature-sensor\/\" target=\"_blank\" rel=\"noopener\">Types of Temperature Sensor\u00a0and Their Application<\/a><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-size: 10pt; font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><a href=\"https:\/\/www.linquip.com\/blog\/types-of-transducers\/\" target=\"_blank\" rel=\"noopener\">Important Detailed Information About The\u00a0Types of Transducers<\/a><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-size: 10pt; font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><a href=\"https:\/\/www.linquip.com\/blog\/solid-vs-stranded-wire\/\" target=\"_blank\" rel=\"noopener\">Solid vs Stranded Wire (A Practical Guide)<\/a><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-size: 10pt; font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><a href=\"https:\/\/www.linquip.com\/blog\/what-is-a-fuse-wire\/\" target=\"_blank\" rel=\"noopener\">What is a Fuse Wire &amp; How Does It Work?<\/a><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-size: 10pt; font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><a href=\"https:\/\/www.linquip.com\/blog\/types-of-electrical-wire\/\" target=\"_blank\" rel=\"noopener\">Types of Electrical Wire + Application (Complete Guide)<\/a><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-size: 10pt; font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><a href=\"https:\/\/www.linquip.com\/blog\/top-machine-shops-in-tampa\/\" target=\"_blank\" rel=\"noopener\">Top 10 Machine Shops in Tampa in 2025 (Clear Guide)<\/a><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-size: 10pt; font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><a href=\"https:\/\/www.linquip.com\/blog\/types-of-molding-machinery\/\" target=\"_blank\" rel=\"noopener\">10 Types of Molding Machinery + PDF (Clear Guide)<\/a><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-size: 10pt; font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><a href=\"https:\/\/www.linquip.com\/blog\/common-types-of-electrical-connectors\/\" target=\"_blank\" rel=\"noopener\">3 Common Types of Electrical Connectors (Clear Guide)<\/a><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-size: 10pt; font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><a href=\"https:\/\/www.linquip.com\/blog\/types-of-sensors-detectors-transducers\/\" target=\"_blank\" rel=\"noopener\">Types of Sensors Detectors\/Transducers: An Entire Guide<\/a><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-size: 10pt; font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><a href=\"https:\/\/www.linquip.com\/blog\/bearing-suppliers-in-usa-worldwide\/\" target=\"_blank\" rel=\"noopener\">Top Bearing Suppliers in USA &amp; Worldwide in 2025<\/a><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-size: 10pt; font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><a href=\"https:\/\/www.linquip.com\/blog\/types-of-electrical-power-connectors\/\" target=\"_blank\" rel=\"noopener\">15 Types of Electrical Power Connectors (Clear Guide) + PDF<\/a><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-size: 10pt; font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><a href=\"https:\/\/www.linquip.com\/blog\/the-best-circuit-breaker-locators-in-2022\/\" target=\"_blank\" rel=\"noopener\">The 8 Best Circuit Breaker Locators in 2025<\/a><\/span><\/strong><\/span><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The earthing of an electricity supply network requires its network plant and customer electrical equipment to be connected to earth to promote safety and reduce the possibility of damage to equipment. Effective earthing prevents long-term over voltages and minimizes the risk of electric shock hazards. Earthing also provides a predetermined path for earth leakage currents, &#8230;<\/p>\n","protected":false},"author":4,"featured_media":2896,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"categories":[21],"tags":[],"class_list":["post-2893","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electrical-component"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/posts\/2893","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/comments?post=2893"}],"version-history":[{"count":8,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/posts\/2893\/revisions"}],"predecessor-version":[{"id":36532,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/posts\/2893\/revisions\/36532"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/media\/2896"}],"wp:attachment":[{"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/media?parent=2893"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/categories?post=2893"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/tags?post=2893"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}