{"id":4720,"date":"2021-02-14T09:00:53","date_gmt":"2021-02-14T17:00:53","guid":{"rendered":"https:\/\/www.linquip.com\/blog\/?p=4720"},"modified":"2023-04-17T22:12:10","modified_gmt":"2023-04-18T06:12:10","slug":"efficiency-of-heat-exchanger","status":"publish","type":"post","link":"https:\/\/www.linquip.com\/blog\/efficiency-of-heat-exchanger\/","title":{"rendered":"How to Calculate the Efficiency of Heat Exchangers?"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_83 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.linquip.com\/blog\/efficiency-of-heat-exchanger\/#How_We_Write_this_Blog_Post_about_How_to_Calculate_the_Efficiency_of_Heat_Exchangers\" >How We Write this Blog Post about How to Calculate the Efficiency of Heat Exchangers?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.linquip.com\/blog\/efficiency-of-heat-exchanger\/#Analysis_of_a_Heat_Exchanger\" >Analysis of a Heat Exchanger\u00a0<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.linquip.com\/blog\/efficiency-of-heat-exchanger\/#What_Factors_Affect_the_Efficiency_of_Heat_Exchangers\" >What Factors Affect the Efficiency of Heat Exchangers?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.linquip.com\/blog\/efficiency-of-heat-exchanger\/#Which_Is_the_Most_Efficient_Heat_Exchanger\" >Which Is the Most Efficient Heat Exchanger?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.linquip.com\/blog\/efficiency-of-heat-exchanger\/#FAQs_about_How_to_Calculate_the_Efficiency_of_Heat_Exchangers\" >FAQs about How to Calculate the Efficiency of Heat Exchangers<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.linquip.com\/blog\/efficiency-of-heat-exchanger\/#Conclusion\" >Conclusion<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.linquip.com\/blog\/efficiency-of-heat-exchanger\/#Download_Efficiency_of_Heat_Exchanger_PDF\" >Download Efficiency of Heat Exchanger PDF<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.linquip.com\/blog\/efficiency-of-heat-exchanger\/#Watch_Videos_about_How_to_Calculate_the_Efficiency_of_Heat_Exchangers\" >Watch Videos about How to Calculate the Efficiency of Heat Exchangers?<\/a><\/li><\/ul><\/nav><\/div>\n<p>The term efficiency of heat exchanger is not defined as a unique concept in scientific resources. However, to determine the efficiency of any system, an ideal state is considered, based on which the degree of proximity of the system to that state is defined as efficiency. In the case of a heat exchanger, the ideal state is not definitively determined. But methods are provided for this purpose, which we will discuss below.<\/p>\n<p><span style=\"font-weight: 400;\">On Linquip&#8217;s website, you can read all the information you need about heat exchanger equipment and devices. Linquip&#8217;s team of experts is happy to answer any questions you might have about heat exchangers. If you are curious to find out more about heat exchangers, you should check out Linquip&#8217;s article, &#8220;<\/span><a href=\"https:\/\/www.linquip.com\/industrial-directories\/253\/heat-exchanger\"><b>What Is Heat Exchanger?<\/b><\/a><span style=\"font-weight: 400;\">&#8220;.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">See a list of Linquip&#8217;s<\/span><a href=\"https:\/\/www.linquip.com\/equipment\/253\/heat-exchanger\"> <b>Heat Exchanger Products<\/b><\/a><span style=\"font-weight: 400;\"> to discover a range of heat exchanger devices &amp; equipment. Also, you can register as a<\/span><a href=\"https:\/\/www.linquip.com\/experts?category_id=253&amp;cn=heat-exchanger\"> <b>Linquip Heat Exchanger Expert<\/b><\/a><span style=\"font-weight: 400;\"> to take advantage of all the offered features. What do you think of the idea of<\/span><a href=\"https:\/\/www.linquip.com\/promotions\/guest-post\"> <b>Guest Posting<\/b><\/a><span style=\"font-weight: 400;\"> on Linquip? The Linquip platform provides you with the option to submit your content as a guest.<\/span><\/p>\n<p style=\"text-align: center;\"><span style=\"text-decoration: underline;\"><span style=\"font-size: 14pt;\"><strong><a title=\"\u21d2 View a List of Heat Exchangers for Sale and Their Suppliers \u21d0\" href=\"https:\/\/www.linquip.com\/industrial-directories\/253\/heat-exchanger\/for-sale\/?utm_source=blog&amp;utm_medium=content&amp;utm_campaign=CRO&amp;utm_term=efficiency%20of%20heat%20exchanger&amp;utm_content=for_sale\" target=\"_blank\" rel=\"noopener\">\u21d2 View a List of Heat Exchangers for Sale and Their Suppliers \u21d0<\/a><\/strong><\/span><\/span><\/p>\n<h2><\/h2>\n<h2><span class=\"ez-toc-section\" id=\"How_We_Write_this_Blog_Post_about_How_to_Calculate_the_Efficiency_of_Heat_Exchangers\"><\/span>How We Write this Blog Post <span style=\"font-size: 27.2px;\">about How<\/span> to Calculate the Efficiency of Heat Exchangers?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Heat exchangers are devices that transfer heat between two or more fluids. They are used in many industrial applications, such as power plants, chemical plants, and refrigeration systems. The efficiency of a heat exchanger is a measure of how well it transfers heat from one fluid to another. It is essential to calculate the efficiency of a heat exchanger to ensure that it is operating correctly and efficiently. A poorly performing heat exchanger can lead to increased energy consumption, reduced productivity, and even equipment failure.<\/p>\n<p>Writing a blog post about calculating the efficiency of heat exchangers requires some experience in the field. We had knowledge about the types of heat exchangers and their applications. We also had experience in calculating the efficiency of heat exchangers using different methods such as LMTD (Logarithmic Mean Temperature Difference) and NTU (Number of Transfer Units). We also provide tips and tricks for calculating the efficiency of heat exchangers and discuss common mistakes that people make when calculating efficiency.<\/p>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Analysis_of_a_Heat_Exchanger\"><\/span><strong>Analysis of a Heat Exchanger\u00a0<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>There are generally two ways to evaluate the performance of heat exchangers. One is Log Mean Temperature Difference, abbreviated as LMTD, and the other is the Effectiveness NTU-method, denoted by \u03b5-NTU.<\/p>\n<p>Meanwhile, by defining the efficiency of heat exchangers, another general method can be considered as a method for analyzing the performance of heat exchangers. This criterion shows how far the heat exchanger is from its best and most ideal design point and how much change it needs to reach this desired state.<\/p>\n<figure id=\"attachment_17221\" aria-describedby=\"caption-attachment-17221\" style=\"width: 640px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"size-full wp-image-17221\" src=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/02\/imageoek7.webp\" alt=\"efficiency of heat exchanger\" width=\"640\" height=\"406\" title=\"\" srcset=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/02\/imageoek7.webp 640w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/02\/imageoek7-300x190.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\" \/><figcaption id=\"caption-attachment-17221\" class=\"wp-caption-text\">An overall schematic of a plate heat exchanger (Reference: <strong>alfalaval.my<\/strong>)<\/figcaption><\/figure>\n<h3><\/h3>\n<h3><strong>Definition of Efficiency of a Heat Exchanger<\/strong><\/h3>\n<p>The heat exchange process between two fluids with different temperatures using solid walls occurs in various engineering applications. The tool to achieve this exchange is a heat exchanger. Some applications like <a href=\"https:\/\/en.wikipedia.org\/wiki\/Air_conditioning#:~:text=Air%20conditioning%20(often%20referred%20to,both%20domestic%20and%20commercial%20environments.\" target=\"_blank\" rel=\"noopener\">air conditioning<\/a>, power generation, waste <a href=\"https:\/\/en.wikipedia.org\/wiki\/Heat_recovery_ventilation\" target=\"_blank\" rel=\"noopener\">heat recovery<\/a>, and chemical processing use this device.<\/p>\n<p>The basis of the work of a heat exchanger is that the hot fluid enters the heat exchanger at temperature T<sub>1<\/sub> and its heat capacity is C<sub>hot<\/sub>. Also, the cold fluid with the heat capacity of C<sub>cold<\/sub> enters temperature t<sub>1<\/sub>; in the meantime, the hot fluid loses its heat, and its temperature drops to T<sub>2<\/sub>. It delivers heat to the cold fluid to increase its temperature to t<sub>2<\/sub> and leave the heat exchanger at this temperature.<\/p>\n<figure id=\"attachment_4721\" aria-describedby=\"caption-attachment-4721\" style=\"width: 250px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"wp-image-4721 size-full\" src=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/02\/heat-exchanger-simple-shchematic.png\" alt=\"efficiency of heat exchanger\" width=\"250\" height=\"202\" title=\"\"><figcaption id=\"caption-attachment-4721\" class=\"wp-caption-text\">A simple schematic of a heat exchanger (Reference: <strong>energyeducation.ca<\/strong>)<\/figcaption><\/figure>\n<p>In general, the efficiency of heat exchange is defined as the ratio of the amount of heat transferred in the actual case to the amount of heat in the ideal case, in the optimal case (equation below).<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\eta =\\frac{q_{act}}{q_{ideal}}<\/span>\n<p>&nbsp;<\/p>\n<p>The heat transfer rate in the actual state is defined as the basis of the rate of change of cold or hot fluid temperature.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">q_{act}=C_{hot}\\left(T_1-T_2\\right)<\/span>\n<p>&nbsp;<\/p>\n<p>Or<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">q_{act}=C_{cold}\\left(t_2-t_1\\right)<\/span>\n<p>&nbsp;<\/p>\n<p>Also, the optimal heat transfer can be calculated as the following equation.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">q_{ideal}=UA\\left(\\overline{T}-\\overline{t}\\right)<\/span>\n<p>&nbsp;<\/p>\n<p>We denote the surface at which heat exchange takes place by A. Also, the <a href=\"https:\/\/en.wikipedia.org\/wiki\/Heat_transfer_coefficient\" target=\"_blank\" rel=\"noopener\">overall average heat transfer coefficient<\/a> is equal to U. The phrase in parentheses is called the Arithmetic Mean Temperature Difference (abbreviated as AMTD) and is calculated as follows.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\overline{T}-\\overline{t}\\mathrm{=}\\frac{T_1+T_2}{2}-\\frac{t_1+t_2}{2}<\/span>\n<p>&nbsp;<\/p>\n<p>The best heat transfer occurs in the case of the counter flow heat exchanger.<\/p>\n<p>Also, to find the overall average heat transfer coefficient (U) we can use the following relationship.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\frac{1}{UA}=\\frac{1}{U_{hot}A_{hot}}=\\frac{1}{U_{cold}A_{cold}}<\/span>\n<p>&nbsp;<\/p>\n<p>A general equation can be used to calculate the efficiency of heat exchanger developed for a number of known exchangers.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\eta =\\frac{{\\mathrm{tanh} \\left(Fa\\right)\\ }}{Fa}<\/span>\n<p>&nbsp;<\/p>\n<p>In the equation above, <em>Fa<\/em> is the fin analogy number which can be evaluated for some common heat exchanger as what follows. In the following section, we refer to counter flow and parallel flow heat exchangers.<\/p>\n<p>&nbsp;<\/p>\n<h4><strong>Counter Flow Heat Exchanger<\/strong><\/h4>\n<p>The direction of flow of hot and cold fluids in counter flow converters is the opposite. In this can we have the following relation to calculate Fa.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">Fa=NTU\\frac{(1-C_r)}{2}<\/span>\n<p>&nbsp;<\/p>\n<p>In this equation, NTU is the number of transfer units and is equal to:<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">NTU=\\frac{UA}{C_{min}}<\/span>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\">\u00a0<span class=\"katex-eq\" data-katex-display=\"false\">C{_{min}}=min(C{_{hot}},C{_{cold}})<\/span>\n<p>&nbsp;<\/p>\n<p>Also, C<sub>r<\/sub> is the capacity ratio and defined as:<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">C_r=\\frac{C_{min}}{C_{max}}<\/span>\n<p>&nbsp;<\/p>\n<h4><strong>Parallel Flow Heat Exchanger<\/strong><\/h4>\n<p>In a parallel flow heat exchanger, hot and cold fluids move in the same direction. To find Fa the following relation is suggested.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">Fa=NTU\\frac{(1+C_r)}{2}<\/span>\n<p>&nbsp;<\/p>\n<figure id=\"attachment_4722\" aria-describedby=\"caption-attachment-4722\" style=\"width: 400px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"wp-image-4722 size-full\" src=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/02\/main-qimg-f60c7075b7cbce9155e27fc2b9bd6b73.gif\" alt=\"efficiency of heat exchanger\" width=\"400\" height=\"478\" title=\"\"><figcaption id=\"caption-attachment-4722\" class=\"wp-caption-text\">Comparison between the structure of parallel flow and counter flow heat exchangers (Reference: <strong>quora.com<\/strong>)<\/figcaption><\/figure>\n<h3><\/h3>\n<h3><strong>Evaluating the Heat Exchanger Using LMTD Method\u00a0<\/strong><\/h3>\n<p>Consider q is the rate of heat transfer within a heat exchanger between the hot and cold fluids. Because heat transfer between the exchanger and its surroundings is negligible, we rewrite the transferred heat based on the parameters we defined in previous parts as following.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">q=C_{hot}\\left(T_1-T_2\\right)=C_{cold}\\left(t_2-t_1\\right)<\/span>\n<p>&nbsp;<\/p>\n<p>The temperatures in the equations point to the mean fluid temperatures at the designated sections.<\/p>\n<p>To write the heat transfer using the overall heat transfer coefficient, we consider another expression as follows.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\mathrm{\\Delta }\\mathrm{T}=T_{hot}-T_{cold}<\/span>\n<p>&nbsp;<\/p>\n<p>Since \u0394T varies with location through the heat exchanger, it is important to deal with an equation in the form of:<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">q=UA\\mathrm{\\Delta }T_m<\/span>\n<p>&nbsp;<\/p>\n<p><em>\u0394T<sub>m<\/sub><\/em> is mean temperature difference. Now, we need to establish an expression for this parameter. It is shown in the references that the appropriate temperature difference should be expressed based on the logarithmic mean temperature difference, which is defined as follows.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\mathrm{\\Delta }T_m=\\mathrm{\\Delta }T_{lm}=\\frac{\\mathrm{\\Delta }T_1-\\mathrm{\\Delta }T_2}{{\\mathrm{ln} \\left(\\frac{\\mathrm{\\Delta }T_1}{\\mathrm{\\Delta }T_2}\\right)\\ }}=\\frac{\\mathrm{\\Delta }T_2-\\mathrm{\\Delta }T_1}{{\\mathrm{ln} \\left(\\frac{\\mathrm{\\Delta }T_2}{\\mathrm{\\Delta }T_1}\\right)\\ }}<\/span>\n<p>&nbsp;<\/p>\n<p>Thus,<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">q=UA\\mathrm{\\Delta }T_{lm}<\/span>\n<p>&nbsp;<\/p>\n<p>In the definition of logarithmic mean temperature difference (LMTD), indices 1 and 2 are related to the sections from which entry or exit occurs. This means that one of the following two conditions happens.<\/p>\n<h4><\/h4>\n<h4><strong>Parallel Flow Heat Exchanger<\/strong><\/h4>\n<p>In this type of heat exchangers, as two fluids enter and exit in the same directions, we have:<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\mathrm{\\Delta }T_1=T_1-t_1<\/span>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\mathrm{\\Delta }T_2=T_2-t_2<\/span>\n<p>&nbsp;<\/p>\n<h4><strong>Counter Flow Heat Exchanger\u00a0<\/strong><\/h4>\n<p>Since in counter flow heat exchangers, hot and cold fluid flows enter or leave in opposite directions:<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\mathrm{\\Delta }T_1=T_1-t_2<\/span>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\mathrm{\\Delta }T_2=T_2-t_1<\/span>\n<p>&nbsp;<\/p>\n<p>Based on these equations, the calculation of the actual heat transfer can be performed.<\/p>\n<figure id=\"attachment_4723\" aria-describedby=\"caption-attachment-4723\" style=\"width: 703px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"wp-image-4723 size-full\" src=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/02\/lmtd.png\" alt=\"efficiency of heat exchanger\" width=\"703\" height=\"287\" title=\"\" srcset=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/02\/lmtd.png 703w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/02\/lmtd-300x122.png 300w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/02\/lmtd-696x284.png 696w\" sizes=\"(max-width: 703px) 100vw, 703px\" \/><figcaption id=\"caption-attachment-4723\" class=\"wp-caption-text\">How to calculate temperature differences in the LMTD method for a counter flow heat exchanger (Reference: <strong>virginiaheattransfer.com<\/strong>)<\/figcaption><\/figure>\n<h3><\/h3>\n<h3><strong>Evaluating the Heat Exchanger Using \u03b5-NTU Method\u00a0<\/strong><\/h3>\n<p>Based on this method, the effectiveness of the exchanger is defined. Of course, it is necessary to determine the maximum allowable heat transfer rate from a heat exchanger. This amount can be achieved by a counter flow heat exchanger of infinite length. In such an exchanger, one of the two fluids will have the maximum allowable temperature change; that&#8217;s mean:<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">{\\mathrm{\\Delta }T}_{max}=T_1-t_1<\/span>\n<p>&nbsp;<\/p>\n<p>The first case is to assume C<sub>c<\/sub>&lt;C<sub>h<\/sub>. Then we have:<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">q_{max}=C_c\\left(T_1-t_1\\right)<\/span>\n<p>&nbsp;<\/p>\n<p>And if C<sub>c<\/sub>&gt;C<sub>h<\/sub>, the maximum allowable heat transfer is:<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">q_{max}=C_h\\left(T_1-t_1\\right)<\/span>\n<p>&nbsp;<\/p>\n<p>After summarizing the last two relationships, we can write:<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">q_{max}=C_{min}\\left(T_1-t_1\\right)<\/span>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">C_{min}={\\mathrm{min} \\left\\{C_c,C_h\\right\\}\\ }<\/span>\n<p>&nbsp;<\/p>\n<p>The efficiency of the heat exchanger or its effectiveness can now be defined as follows:<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\varepsilon =\\frac{q}{q_{max}}<\/span>\n<p>&nbsp;<\/p>\n<p>It can be shown for each heat exchanger:<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\varepsilon =f\\left(NTU,\\ C_r\\right)<\/span>\n<p>&nbsp;<\/p>\n<p>Both NTU and C<sub>r<\/sub> are introduced in the previous sections. There are some relations developed to calculate the function mentioned above. Each expression belongs to a specific class of exchangers. In the following, some of these classes and the related equations are presented.<\/p>\n<h4><\/h4>\n<h4><strong>Parallel Flow Heat Exchanger<\/strong><\/h4>\n<p>Efficiency of heat exchanger with the parallel arrangement is:<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\varepsilon =\\frac{1-{\\mathrm{exp} [-NTU\\left(1+C_r\\right)]\\ }}{1+C_r}<\/span>\n<p>&nbsp;<\/p>\n<h4><strong>Counter Flow Heat Exchanger\u00a0<\/strong><\/h4>\n<p>Efficiency of heat exchanger with the parallel pattern is:<\/p>\n<p>(C\u00ad<sub>r<\/sub>&lt;1)<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\varepsilon =\\frac{1-{\\mathrm{exp} [-NTU\\left(1-C_r\\right)]\\ }}{1-C_r{\\mathrm{exp} [-NTU\\left(1-C_r\\right)]\\ }}<\/span>\n<p>&nbsp;<\/p>\n<p>(C\u00ad<sub>r<\/sub>=1)<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\varepsilon =\\frac{NTU}{1+NTU}<\/span>\n<p>&nbsp;<\/p>\n<h4><strong>Shell and Tube Heat Exchanger\u00a0<\/strong><\/h4>\n<p>Efficiency of heat exchanger with the <a href=\"https:\/\/en.wikipedia.org\/wiki\/Shell_and_tube_heat_exchanger\" target=\"_blank\" rel=\"noopener\">shell and tube<\/a> structure (n shell passes) is:<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\varepsilon =\\left[{\\left(\\frac{1-{\\varepsilon }_1C_r}{1-{\\varepsilon }_1}\\right)}^n-1\\right]-\\left[{\\left(\\frac{1-{\\varepsilon }_1C_r}{1-{\\varepsilon }_1}\\right)}^n-C_r\\right]<\/span>\n<p>&nbsp;<\/p>\n<p>Where \u03b5<sub>1<\/sub> is the efficiency of heat exchanger with one pass shell and tube structure.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">{\\varepsilon }_1=2{\\left[1+C_r+{\\left(1+C^2_r\\right)}^{\\frac{1}{2}}\\times \\frac{1+{\\mathrm{exp} {\\left[-(NTU\\right)}_1{\\left(1+C^2_r\\right)}^{\\frac{1}{2}}]\\ \\ }}{1-{\\mathrm{exp} {\\left[-(NTU\\right)}_1{\\left(1+C^2_r\\right)}^{\\frac{1}{2}}]\\ \\ }}\\right]}^{-1}<\/span>\n<p>&nbsp;<\/p>\n<h4><strong>Cross Flow Heat Exchanger\u00a0<\/strong><\/h4>\n<p>To calculate the efficiency of heat exchanger with <a href=\"https:\/\/en.wikipedia.org\/wiki\/Heat_exchanger\" target=\"_blank\" rel=\"noopener\">cross flow<\/a> formation, usually, a correction factor is regarded for the logarithmic mean temperature difference. This means:<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\mathrm{\\Delta }T_{lm}=F\\mathrm{\\Delta }T_{lm.counter\\ flow}<\/span>\n<p>&nbsp;<\/p>\n<p>The correction factor is determined using diagrams for different types of heat exchangers.<\/p>\n<p>In the following figure, you can see the curves to find the effectiveness of a cross flow heat exchanger for different values of NTU and C<sub>r<\/sub>.<\/p>\n<figure id=\"attachment_4724\" aria-describedby=\"caption-attachment-4724\" style=\"width: 537px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"wp-image-4724 size-full\" src=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/02\/e_NTU_Cross_Flow.png\" alt=\"efficiency of heat exchanger\" width=\"537\" height=\"382\" title=\"\" srcset=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/02\/e_NTU_Cross_Flow.png 537w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/02\/e_NTU_Cross_Flow-300x213.png 300w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/02\/e_NTU_Cross_Flow-100x70.png 100w\" sizes=\"(max-width: 537px) 100vw, 537px\" \/><figcaption id=\"caption-attachment-4724\" class=\"wp-caption-text\">Effectiveness-NTU curves for different values of Cr (Reference: <strong>cheguide.com<\/strong>)<\/figcaption><\/figure>\n<h4><\/h4>\n<h4><strong>Heat Exchangers with C<sub>r<\/sub>=0<\/strong><\/h4>\n<p>The efficiency of heat exchanger is calculated with the following equation.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><span class=\"katex-eq\" data-katex-display=\"false\">\\varepsilon =1-{\\mathrm{exp} \\left(-NTU\\right)\\ }<\/span>\n<h2><\/h2>\n<h2><span class=\"ez-toc-section\" id=\"What_Factors_Affect_the_Efficiency_of_Heat_Exchangers\"><\/span><b>What Factors Affect the Efficiency of Heat Exchangers?<\/b><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Heat exchanger efficiency is highly influenced by the velocity of the operating fluid, so increasing the flow rate is recommended from time to time. The increased turbulence prevents fouling tendencies that would otherwise damage the heat exchangers and impede fluid flow.<\/span><\/p>\n<h2><\/h2>\n<h2><span class=\"ez-toc-section\" id=\"Which_Is_the_Most_Efficient_Heat_Exchanger\"><\/span><b>Which Is the Most Efficient Heat Exchanger?<\/b><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Plate exchangers are the most efficient because they have turbulent flow on both sides. High heat transfer coefficient and turbulence caused by the even distribution of flow are important. Regenerative plate heat exchangers, however, are limited to low viscosities. It may be necessary to use a special tubular for high viscosities.<\/span><\/p>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"FAQs_about_How_to_Calculate_the_Efficiency_of_Heat_Exchangers\"><\/span><b>FAQs about How to Calculate the Efficiency of Heat Exchangers<\/b><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><em><strong>What affects heat exchanger efficiency?<\/strong><\/em><\/p>\n<p>The opening temperature of the heat pipe, the rate of fluid filling, the physical properties of the liquid refrigerant, the work temperature of the tube, the angle, the tube spacing, the tube length, the hot and cold fluid flow, and wind speed are just a few of the variables that affect how well a heat pipe heat exchanger transfers heat.<\/p>\n<p><em><strong>What is the best efficiency of heat exchanger?<\/strong><\/em><\/p>\n<p>Even when such characteristics are taken into account in estimates made by the industry, plate heat exchangers are still routinely proven to be the most efficient of all heat exchangers. They frequently reach efficiency levels of around 90%.<\/p>\n<p><em><strong>How do you prevent a heat exchanger from failing?<\/strong><\/em><\/p>\n<p>The majority of failures in steam-heated exchangers are caused by fluid thermal expansion. In the heated fluid system, relief valves can be placed to help avoid failure brought on by thermal expansion and cycling. It&#8217;s also a good idea to provide a way to handle fluid expansion.<\/p>\n<p><em><strong>Why is the efficiency of a heat exchanger important?<\/strong><\/em><\/p>\n<p>It is often suggested to increase the flow rate because the speed of the working fluid has a big effect on how well the heat exchanger works. Increased turbulence reduces the likelihood of fouling, which might harm heat exchangers and obstruct fluid flow.<\/p>\n<p><em><strong>How efficient is a heat exchanger temperature?<\/strong><\/em><\/p>\n<p>The ratio between the actual heat transfer in a heat exchanger and the ideal heat transfer rate is known as the heat exchanger efficiency.<\/p>\n<p><em><strong>How can thermal efficiency be improved?<\/strong><\/em><\/p>\n<p>The thermal efficiency of gasoline engines may be improved by diluting and increasing the compression ratio. Slow combustion, greater cooling loss, and engine banging are among the problems that are related to increased compression ratios.<\/p>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span><strong>Conclusion<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>In this article, we reviewed the efficiency of heat exchanger, explained the methods introduced to calculate this parameter, and mentioned the equations for different types of heat exchangers.<\/p>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Download_Efficiency_of_Heat_Exchanger_PDF\"><\/span><strong>Download Efficiency of Heat Exchanger PDF<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>This article may be downloaded as a PDF so you can access it whenever you like.<\/p>\n<div class=\"su-button-center\"><a href=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/02\/linquip.com-How-to-Calculate-the-Efficiency-of-Heat-Exchangers.pdf\" class=\"su-button su-button-style-default su-button-wide\" style=\"color:#FFFFFF;background-color:#2D89EF;border-color:#246ec0;border-radius:12px\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"color:#FFFFFF;padding:0px 30px;font-size:22px;line-height:44px;border-color:#6cadf4;border-radius:12px;text-shadow:none\"> Download PDF<\/span><\/a><\/div>\n<h2><\/h2>\n<h2><span class=\"ez-toc-section\" id=\"Watch_Videos_about_How_to_Calculate_the_Efficiency_of_Heat_Exchangers\"><\/span><strong>Watch Videos about How to Calculate the Efficiency of Heat Exchangers?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For more information about How to Calculate the Efficiency of Heat Exchangers, watch the following video.<\/p>\n<p><iframe loading=\"lazy\" src=\"\/\/www.youtube.com\/embed\/2uPgIgZjumM\" width=\"560\" height=\"314\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<p>&nbsp;<\/p>\n<h3><b>Buy Equipment or Ask for a Service<\/b><\/h3>\n<p>By using Linquip RFQ Service, you can expect\u00a0to receive quotations from various suppliers across multiple industries and regions.<\/p>\n<p style=\"text-align: center;\"><strong><a href=\"http:\/\/linquip.com\/get-quote?utm_source=blog&amp;utm_medium=content&amp;utm_campaign=product_list&amp;utm_term=product_list&amp;utm_content=rfq\" target=\"_blank\" rel=\"noopener\">Click Here to Request a Quotation From Suppliers and Service Providers<\/a><\/strong><\/p>\n<p><em><strong>Read More on Linquip<\/strong><\/em><\/p>\n<ul>\n<li><span style=\"text-decoration: underline;\"><strong><span style=\"font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><a title=\"What is the Difference between Heat and Temperature?\" href=\"https:\/\/www.linquip.com\/blog\/difference-between-heat-and-temperature\/\" target=\"_blank\" rel=\"noopener\">What is the Difference between Heat and Temperature?<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"text-decoration: underline;\"><strong><span style=\"font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><a title=\"Difference Between Grounding and Earthing\" href=\"https:\/\/www.linquip.com\/blog\/difference-between-grounding-and-earthing\/\" target=\"_blank\" rel=\"noopener\" data-schema-attribute=\"\">Difference Between Grounding and Earthing<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"text-decoration: underline;\"><strong><span style=\"font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><a title=\"Steam Turbine Efficiency: Complete Explanation\" href=\"https:\/\/www.linquip.com\/blog\/steam-turbine-efficiency-complete-explanation\/\" target=\"_blank\" rel=\"noopener\">Steam Turbine Efficiency: Complete Explanation<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"text-decoration: underline;\"><strong><span style=\"font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/how-to-use-and-read-a-hydrometer\/\" target=\"_blank\" rel=\"noopener\">How to Use and Read a Hydrometer: Ultimate Guide<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"text-decoration: underline;\"><strong><span style=\"font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/how-to-use-a-refractometer\/\" target=\"_blank\" rel=\"noopener\">How to Use a Refractometer: Practical Guide<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"text-decoration: underline;\"><strong><span style=\"font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/difference-between-density-and-relative-density\/\" target=\"_blank\" rel=\"noopener\">Difference between Density and Relative Density<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"text-decoration: underline;\"><strong><span style=\"font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/difference-between-electric-and-magnetic-field\/\" target=\"_blank\" rel=\"noopener\">Difference between Electric and Magnetic Fields<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"text-decoration: underline;\"><strong><span style=\"font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/difference-between-orbit-and-orbital\/\" target=\"_blank\" rel=\"noopener\">Difference between Orbit and Orbital<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"text-decoration: underline;\"><strong><span style=\"font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/how-to-fix-water-hammer-dangers-and-tips\/\" target=\"_blank\" rel=\"noopener\">How to fix Water Hammer? Dangers and Tips<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"text-decoration: underline;\"><strong><span style=\"font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/what-is-water-hammer\/\" target=\"_blank\" rel=\"noopener\">What Is Water Hammer and How to Fix it?<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"text-decoration: underline;\"><strong><span style=\"font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/what-is-industrial-marketing\/\" target=\"_blank\" rel=\"noopener\">What is Industrial Marketing? {Full Guide}<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"text-decoration: underline;\"><strong><span style=\"font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/steam-turbine-efficiency-complete-explanation\/\" target=\"_blank\" rel=\"noopener\">Steam Turbine Efficiency: Complete Explanation<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"text-decoration: underline;\"><strong><span style=\"font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/difference-between-scalar-and-vector-quantity\/\" target=\"_blank\" rel=\"noopener\">Difference Between Scalar and Vector Quantity<\/a><\/span><\/span><\/strong><\/span><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The term efficiency of heat exchanger is not defined as a unique concept in scientific resources. However, to determine the efficiency of any system, an ideal state is considered, based on which the degree of proximity of the system to that state is defined as efficiency. In the case of a heat exchanger, the ideal &#8230;<\/p>\n","protected":false},"author":11,"featured_media":28861,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"categories":[24,8],"tags":[],"class_list":["post-4720","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-science","category-heat-exchanger"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/posts\/4720","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/comments?post=4720"}],"version-history":[{"count":10,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/posts\/4720\/revisions"}],"predecessor-version":[{"id":28862,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/posts\/4720\/revisions\/28862"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/media\/28861"}],"wp:attachment":[{"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/media?parent=4720"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/categories?post=4720"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/tags?post=4720"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}