{"id":7009,"date":"2021-04-13T09:00:50","date_gmt":"2021-04-13T17:00:50","guid":{"rendered":"https:\/\/www.linquip.com\/blog\/?p=7009"},"modified":"2026-02-27T10:15:35","modified_gmt":"2026-02-27T18:15:35","slug":"split-phase-induction-motors","status":"publish","type":"post","link":"https:\/\/www.linquip.com\/blog\/split-phase-induction-motors\/","title":{"rendered":"What Is Split Phase Induction Motors? 2026 Ultimate Guide"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.linquip.com\/blog\/split-phase-induction-motors\/#Construction\" >Construction<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.linquip.com\/blog\/split-phase-induction-motors\/#Working_Principle\" >Working Principle<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.linquip.com\/blog\/split-phase-induction-motors\/#Performance_and_Characteristics\" >Performance and Characteristics<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.linquip.com\/blog\/split-phase-induction-motors\/#Types\" >Types<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.linquip.com\/blog\/split-phase-induction-motors\/#Advantages\" >Advantages<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.linquip.com\/blog\/split-phase-induction-motors\/#Disadvantages\" >Disadvantages<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.linquip.com\/blog\/split-phase-induction-motors\/#Application\" >Application<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.linquip.com\/blog\/split-phase-induction-motors\/#Download_Split_Phase_Induction_Motors_PDF\" >Download Split Phase Induction Motors PDF<\/a><\/li><\/ul><\/nav><\/div>\n<p><span style=\"font-weight: 400;\">The split-phase induction motor is one of the common single-phase AC motors. It has economic benefits and the requirement of this power system in most of the applications are homes, shops,\u00a0 industry, offices, etc. One of the advantages of this type of single-phase motor is its ability to regenerate power automatically on descending grades. In this article, we find the best answer to the question of <\/span><span style=\"font-weight: 400;\">what is split-phase induction motors<\/span><span style=\"font-weight: 400;\"> and discuss an overview of split-phase induction motor construction, working, characteristics, types, advantages, disadvantages, and their applications. Follow this new blog in Linquip to find out more about this motor.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">On the Linquip platform, you can find all the information you need about induction motors equipment and devices. Our experts are available to answer any questions you may have about the split phase induction motor. To get started, read Linquip&#8217;s article titled, &#8220;<\/span><b>What is Split Phase Induction Motor?<\/b><span style=\"font-weight: 400;\">&#8220;. You need to register as a<\/span><a href=\"https:\/\/www.linquip.com\/experts\/leaderboard\"> <b>Linquip Expert<\/b><\/a><span style=\"font-weight: 400;\"> in order to access all of the Linquip benefits.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Have you ever considered<\/span><a href=\"https:\/\/www.linquip.com\/blog\/user-guest-post\"> <b>Guest Posting<\/b><\/a><span style=\"font-weight: 400;\"> on the Linquip platform? There is an option for guests to submit their own posts on Linquip.<\/span><\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-7034\" src=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Split-phase-induction-motor-SPIM-circuit-wiring-diagram-and-torque-speed-curve.jpg\" alt=\"\" width=\"1072\" height=\"496\" title=\"\" srcset=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Split-phase-induction-motor-SPIM-circuit-wiring-diagram-and-torque-speed-curve.jpg 1072w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Split-phase-induction-motor-SPIM-circuit-wiring-diagram-and-torque-speed-curve-300x139.jpg 300w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Split-phase-induction-motor-SPIM-circuit-wiring-diagram-and-torque-speed-curve-1024x474.jpg 1024w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Split-phase-induction-motor-SPIM-circuit-wiring-diagram-and-torque-speed-curve-768x355.jpg 768w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Split-phase-induction-motor-SPIM-circuit-wiring-diagram-and-torque-speed-curve-696x322.jpg 696w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Split-phase-induction-motor-SPIM-circuit-wiring-diagram-and-torque-speed-curve-1068x494.jpg 1068w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Split-phase-induction-motor-SPIM-circuit-wiring-diagram-and-torque-speed-curve-908x420.jpg 908w\" sizes=\"(max-width: 1072px) 100vw, 1072px\" \/><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Construction\"><\/span>Construction<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">To answer the question of <\/span><span style=\"font-weight: 400;\">what is split-phase induction motors<\/span><span style=\"font-weight: 400;\">, first, let us see what are the different parts of this motor. The split-phase induction motor basically consists of a stator, a rotor, a centrifugal switch located inside the motor, two end shields housing the bearings that support the rotor shaft. In addition to the main winding or running winding, the stator of the split-phase induction motor carries another winding called auxiliary winding or starting winding. A centrifugal switch is connected in series with auxiliary winding. The purpose of this switch is to disconnect the auxiliary winding from the main circuit.\u00a0<\/span><\/p>\n<figure id=\"attachment_17436\" aria-describedby=\"caption-attachment-17436\" style=\"width: 470px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"size-full wp-image-17436\" src=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/construction.png\" alt=\"Split Phase Induction Motors\" width=\"470\" height=\"315\" title=\"\" srcset=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/construction.png 470w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/construction-300x201.png 300w\" sizes=\"(max-width: 470px) 100vw, 470px\" \/><figcaption id=\"caption-attachment-17436\" class=\"wp-caption-text\">Construction of split phase induction motor (Reference: <strong>pinterest.com<\/strong>)<\/figcaption><\/figure>\n<p><span style=\"font-weight: 400;\">A split-phase motor has no capacitance in the auxiliary circuit. A phase shift to the main current is achieved by using narrow conductors to achieve high resistance to reactance ratio. Increasing the resistance means that the auxiliary winding can only be used during starting, otherwise, it would overheat. A split-phase motor has significantly lower torque at starting due to the reduced phase angle between main and auxiliary winding currents.<\/span><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Working_Principle\"><\/span>Working Principle<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">In split-phase motor two windings named main winding and starting winding are provided. At the time of starting, both the main and starting windings should be connected across the supply to produce the rotating magnetic field, and when the supply is given to the stator the rotating magnetic field is produced. The rotor is of a squirrel cage type and the revolving magnetic field sweeps part of the stationary rotor, inducing EMF in the rotor.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">As the rotor bars are short-circuited, a current flows through them producing a magnetic field. This magnetic field opposes the revolving magnetic field and will combine with the main field to produce a revolving field. Once the rotor starts rotating and attains a speed up to 75 to 80 percent of the synchronous speed, the starting winding can be disconnected from the supply by the centrifugal switch.<\/span><\/p>\n<figure id=\"attachment_17435\" aria-describedby=\"caption-attachment-17435\" style=\"width: 1600px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"size-full wp-image-17435\" src=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/working.png\" alt=\"Split Phase Induction Motors\" width=\"1600\" height=\"718\" title=\"\" srcset=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/working.png 1600w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/working-300x135.png 300w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/working-1024x460.png 1024w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/working-768x345.png 768w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/working-1536x689.png 1536w\" sizes=\"(max-width: 1600px) 100vw, 1600px\" \/><figcaption id=\"caption-attachment-17435\" class=\"wp-caption-text\">Working principle of split phase induction motor (Reference: <strong>studyelectrical.com<\/strong>)<\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Performance_and_Characteristics\"><\/span>Performance and Characteristics<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><span style=\"font-weight: 400;\">The starting torque is about twice the full load torque.<\/span><\/li>\n<li><span style=\"font-weight: 400;\">Speed falls with the increase in load with only about 5% to 7% otherwise it is a constant speed motor.<\/span><\/li>\n<li><span style=\"font-weight: 400;\">The current at the start is about 6 to 8 times.<\/span><\/li>\n<li><span style=\"font-weight: 400;\">Actual speed is less than synchronous speed Ns.<\/span><\/li>\n<li><span style=\"font-weight: 400;\">For the same weight, its rating is about 60 percent that of the polyphase motor. The split-phase induction motor has lower p.f. and lesser efficiency. Its P.f. is about 0.6 and efficiency is also about 60%.<\/span><\/li>\n<li><span style=\"font-weight: 400;\">It is suitable for easily starting loads where the frequency of starting is limited. This type of motor is not used for drives that require more than 1 KW because of the low starting torque.<\/span><\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-7032\" src=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Silniki_by_Zureks-scaled.jpg\" alt=\"\" width=\"2560\" height=\"1631\" title=\"\" srcset=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Silniki_by_Zureks-scaled.jpg 2560w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Silniki_by_Zureks-300x191.jpg 300w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Silniki_by_Zureks-1024x653.jpg 1024w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Silniki_by_Zureks-768x489.jpg 768w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Silniki_by_Zureks-1536x979.jpg 1536w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Silniki_by_Zureks-2048x1305.jpg 2048w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Silniki_by_Zureks-696x444.jpg 696w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Silniki_by_Zureks-1392x887.jpg 1392w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Silniki_by_Zureks-1068x681.jpg 1068w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Silniki_by_Zureks-1920x1224.jpg 1920w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/Silniki_by_Zureks-659x420.jpg 659w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Types\"><\/span>Types<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Different types of split-phase induction motors are as follows.<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Shaded pole motors<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Resistance-start induction-run motors<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Capacitor-start induction-run motors<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Capacitor-start capacitor-run motors<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Permanent capacitor single phase induction motor<\/span><\/li>\n<\/ol>\n<h2><span class=\"ez-toc-section\" id=\"Advantages\"><\/span>Advantages<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">The advantages of a split-phase induction motor include the following.<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">The motor is economical and installed in many domestic appliances.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">It can be changed once it wears out before trying to reverse it.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">These are available in different frame sizes so that they can be placed effortlessly in most of the machines.<\/span><\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Disadvantages\"><\/span>Disadvantages<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">The disadvantages of a split-phase induction motor include the following.<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">These motors have less starting torque, so not suitable for above 1 KW.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">The disadvantage of this motor is power output and efficiency. As compared to a 3-phase motor, these are unsuccessful while changing the energy from electrical to working.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">These motors rely simply on the different resistance &amp; inductance of the starting winding.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">These motors are used where high starting torque is mandatory like an air compressor.<\/span><\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Application\"><\/span>Application<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">The applications of this motor include different loads which are used for general purpose. Due to the excellent starting torque and easy direction-reversal characteristics, it finds use in lathe machines, drilling, washing machines, woodworking tools, belted fans, drill presses, oil burners, centrifugal pumps, compressors, air conditioning fans, floor polishers, blowers dryers, mixer grinder, heating blowers with belt-driven and conveyors with tiny belt-driven, and various other low starting torque applications.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">This motor is used where the distribution of the three phases is not required.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">This motor does not give lots of starting torque, thus the load should be quite small, and where mechanical gain can be used to assist the motor to begin.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">So, there you have every single fact to the question of <\/span><span style=\"font-weight: 400;\">what is split-phase induction motors<\/span><span style=\"font-weight: 400;\">. If you enjoyed this article in Linquip, let us know by leaving a reply in the comment section. Is there any question we can help you through? Feel free to <a href=\"https:\/\/www.linquip.com\/sign-up?client_redirect=\/\" target=\"_blank\" rel=\"noopener\" data-schema-attribute=\"\">sign up<\/a> on our website to get the most professional advice from our experts!<\/span><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Download_Split_Phase_Induction_Motors_PDF\"><\/span><b>Download Split Phase Induction Motors PDF<\/b><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">If you wish, you can download a PDF version of this article to keep on your computer for future reference.<\/span><\/p>\n<div class=\"su-button-center\"><a href=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/04\/linquip.com-What-Is-Split-Phase-Induction-Motors-2022-Ultimate-Guide.pdf\" class=\"su-button su-button-style-default su-button-wide\" style=\"color:#FFFFFF;background-color:#2D89EF;border-color:#246ec0;border-radius:12px\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"color:#FFFFFF;padding:0px 30px;font-size:22px;line-height:44px;border-color:#6cadf4;border-radius:12px;text-shadow:none\"> Download PDF<\/span><\/a><\/div>\n<p><em><strong>Read More In Linquip<\/strong><\/em><\/p>\n<ul>\n<li><span style=\"font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/shaded-pole-induction-motors\/\" target=\"_blank\" rel=\"noopener\">What Are Shaded Pole Induction Motors? Ultimate Guide<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/types-of-induction-motor\/\" target=\"_blank\" rel=\"noopener\">Types of Induction Motor: A Concise and Useful Guild<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/what-is-capacitor-start-induction-motor\/\" target=\"_blank\" rel=\"noopener\">What is\u00a0Capacitor Start Induction Motor: A Complete Guide<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/single-phase-induction-motor\/\" target=\"_blank\" rel=\"noopener\">Single-Phase Induction Motor\u00a0: All You Need to Know About It<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/the-only-guide-youll-ever-need-for-the-working-principle-of-induction-motor\/\" target=\"_blank\" rel=\"noopener\">Working Principle of Induction Motor: Full Guide<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/efficiency-of-induction-motor\/\" target=\"_blank\" rel=\"noopener\">Efficiency of Induction Motor: Calculation &amp; Equation<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"font-family: verdana, geneva, sans-serif;\"><strong><span style=\"text-decoration: underline;\"><span style=\"font-size: 10pt;\"><a href=\"https:\/\/www.linquip.com\/blog\/split-phase-induction-motors\/\" target=\"_blank\" rel=\"noopener\">What Is Split Phase Induction Motors? Ultimate Guide<\/a><\/span><\/span><\/strong><\/span><\/li>\n<li><span style=\"text-decoration: underline; font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><strong><a href=\"https:\/\/www.linquip.com\/blog\/synchronous-motors-definition\/\" target=\"_blank\" rel=\"noopener\">Synchronous Motors: Definition, Working Principle, Types, and Applications<\/a><\/strong><\/span><\/span><\/li>\n<li><span style=\"text-decoration: underline; font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><strong><a href=\"https:\/\/www.linquip.com\/blog\/why-is-synchronous-motor-not-self-starting\/\" target=\"_blank\" rel=\"noopener\">Why Is Synchronous Motor Not Self-starting?<\/a><\/strong><\/span><\/span><\/li>\n<li><span style=\"text-decoration: underline; font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><strong><a href=\"https:\/\/www.linquip.com\/blog\/permanent-magnet-synchronous-motors\/\" target=\"_blank\" rel=\"noopener\">The Beginner\u2019s Guide To\u00a0Permanent Magnet Synchronous Motors<\/a><\/strong><\/span><\/span><\/li>\n<li><span style=\"text-decoration: underline; font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><strong><a href=\"https:\/\/www.linquip.com\/blog\/types-of-induction-motor\/\" target=\"_blank\" rel=\"noopener\">Types of Induction Motor: A Concise and Useful Guild<\/a><\/strong><\/span><\/span><\/li>\n<li><span style=\"text-decoration: underline; font-family: verdana, geneva, sans-serif;\"><span style=\"font-size: 10pt;\"><strong><a href=\"https:\/\/www.linquip.com\/blog\/dc-motor-types\/\" target=\"_blank\" rel=\"noopener\">All About\u00a0DC Motor Types\u00a0and Their Applications<\/a><\/strong><\/span><\/span><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The split-phase induction motor is one of the common single-phase AC motors. It has economic benefits and the requirement of this power system in most of the applications are homes, shops,\u00a0 industry, offices, etc. One of the advantages of this type of single-phase motor is its ability to regenerate power automatically on descending grades. In &#8230;<\/p>\n","protected":false},"author":4,"featured_media":7033,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"categories":[12],"tags":[],"class_list":["post-7009","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-motor"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/posts\/7009","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/comments?post=7009"}],"version-history":[{"count":10,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/posts\/7009\/revisions"}],"predecessor-version":[{"id":37792,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/posts\/7009\/revisions\/37792"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/media\/7033"}],"wp:attachment":[{"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/media?parent=7009"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/categories?post=7009"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/tags?post=7009"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}