{"id":8766,"date":"2021-08-09T11:00:17","date_gmt":"2021-08-09T19:00:17","guid":{"rendered":"https:\/\/www.linquip.com\/blog\/?p=8766"},"modified":"2021-09-06T23:06:17","modified_gmt":"2021-09-07T07:06:17","slug":"what-is-floating-head-exchanger","status":"publish","type":"post","link":"https:\/\/www.linquip.com\/blog\/what-is-floating-head-exchanger\/","title":{"rendered":"Quick Guide On What Is Floating Head Exchanger"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">Shell and tube exchangers are the most commonly used heat exchangers in process plants today. One of the main types of shell and tube heat exchangers is the floating head exchanger. This heat exchanger is unlike any shell and tube heat exchanger. It is one of the most used heat exchangers specially designed to be completely stress-free to promote longer equipment life and virtually no maintenance. In this article, we find the best answer to the question of <\/span><span style=\"font-weight: 400;\">what is floating head heat exchanger<\/span><span style=\"font-weight: 400;\">. Follow this new blog in Linquip to find out more about this type of heat exchanger.<\/span><\/p>\n<h2>What Is Floating Head Exchanger?<\/h2>\n<p><span style=\"font-weight: 400;\">The floating head type heat exchanger is a type of shell and tube heat exchanger in which the tube sheet assembly is independent and free to move within the shell or the shell cover. This exchanger is widely used for the service where the temperature is high between the shell and tube bundle that creates expansion issues. The floating head exchanger is the best heat exchanger in terms of efficiency and maintenance but naturally comes at a higher cost.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">This heat exchanger eliminates heat exchanger failure for industry-leading equipment life without any maintenance. Floating head heat exchangers offer unprecedented resistance to the thermal stress and fatigue common in every other type of shell and tube heat exchanger. Special designs of this heat exchanger are available for particulate ladened air streams, corrosive applications, high temperatures and high pressures.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">With high reliability and wide adaptability, the floating head heat exchanger has accumulated a wealth of experience during the long-term using process and promoted its development constantly. So far, among all kinds of heat exchangers, the floating head heat exchanger is still in a leading position.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">This type of heat exchanger can be applied as solutions including:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High thermal efficiencies<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Corrosive airstreams<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Cooling applications<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High Temperatures<\/span><\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"size-full wp-image-8768 aligncenter\" src=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/287_DAC_00566-scaled-1.jpg\" alt=\"What Is Floating Head Exchanger\" width=\"800\" height=\"599\" title=\"\" srcset=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/287_DAC_00566-scaled-1.jpg 800w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/287_DAC_00566-scaled-1-300x225.jpg 300w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/287_DAC_00566-scaled-1-768x575.jpg 768w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/287_DAC_00566-scaled-1-696x521.jpg 696w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/287_DAC_00566-scaled-1-561x420.jpg 561w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/287_DAC_00566-scaled-1-80x60.jpg 80w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/287_DAC_00566-scaled-1-160x120.jpg 160w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/287_DAC_00566-scaled-1-265x198.jpg 265w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<div class=\"su-box su-box-style-default\" id=\"\" style=\"border-color:#00021e;border-radius:3px;max-width:none\"><div class=\"su-box-title\" style=\"background-color:#263551;color:#89cabd;border-top-left-radius:1px;border-top-right-radius:1px\">Read More on Linquip<\/div><div class=\"su-box-content su-u-clearfix su-u-trim\" style=\"border-bottom-left-radius:1px;border-bottom-right-radius:1px\"><a title=\"Types of Heat Exchangers\" href=\"https:\/\/www.linquip.com\/blog\/types-of-heat-exchangers\/\" target=\"_blank\" rel=\"noopener\" data-schema-attribute=\"\">Types of Heat Exchangers<\/a>: An Introduction to All Essential about Specifications<\/div><\/div>\n<h3>Parts<\/h3>\n<p><span style=\"font-weight: 400;\">To answer the question of <\/span><span style=\"font-weight: 400;\">what is floating head heat exchanger<\/span><span style=\"font-weight: 400;\">, first, let us see what its different parts are. As shown in the name of it, in this design, one end of the tube sheet is fixed to the shell, while the other one can \u201cfloat\u201d freely inside the shell. It also consists of a removable tube bundle made up of straight tubes, tube sheets, tie rods, and baffles.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Depending on the weight and length of the bundle, there may also be slides or wheel assemblies to make removal of the tube bundle from the heat exchanger shell easier. The floating tube sheet must be enclosed by a floating head cover. In this equipment, gasket joints are very large, therefore it is costly. Generally, both the shell and tube bundle are free of expansion, this permits no thermal stress is produced between the shell and tube bundle when the temperature difference of the two medium is large.<\/span><\/p>\n<h3>Working Principle<\/h3>\n<p><span style=\"font-weight: 400;\">The working principle of this type of <a href=\"https:\/\/en.wikipedia.org\/wiki\/Heat_exchanger\" target=\"_blank\" rel=\"noopener\" data-schema-attribute=\"\">heat exchanger<\/a> is simple. When the tube side allowable pressure drop is considerably low, and fluid cannot be put in the shell side, a floating head heat exchanger is recommended. The tube-side allowable pressure drop becomes the limiting factor in determining the length and number of tubes, and the shellside pressure drop is maximized within that size by a baffle arrangement that will achieve the necessary performance.<\/span><\/p>\n<div class=\"su-box su-box-style-default\" id=\"\" style=\"border-color:#00021e;border-radius:3px;max-width:none\"><div class=\"su-box-title\" style=\"background-color:#263551;color:#89cabd;border-top-left-radius:1px;border-top-right-radius:1px\">Read More on Linquip<\/div><div class=\"su-box-content su-u-clearfix su-u-trim\" style=\"border-bottom-left-radius:1px;border-bottom-right-radius:1px\">Advanced Guide: <a title=\"What Is Tube In Tube Heat Exchangers\" href=\"https:\/\/www.linquip.com\/blog\/what-is-tube-in-tube-heat-exchangers\/\" target=\"_blank\" rel=\"noopener\" data-schema-attribute=\"\">What Is Tube In Tube Heat Exchangers<\/a><\/div><\/div>\n<h3>Types<\/h3>\n<p><span style=\"font-weight: 400;\">According to different requirements, the floating head on a floating head heat exchanger can be designed into various types. To reduce thermal stresses and provide a means to remove the tube bundle for cleaning, several floating head designs have been established. Here are four basic kinds of floating head heat exchangers:<\/span><b><\/b><\/p>\n<ul>\n<li aria-level=\"1\">\n<h4>Split Back Ring Type (Type S)<\/h4>\n<\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Split back ring type unit is more commonly used in industries. In this type of construction, the floating head is fitted to the tube sheet which is away from the channel. The floating head is held in position by a split backing ring so that dismantling is possible. The floating tube sheet diameter is kept slightly smaller than the inner shell diameter so that the entire tube bundle can be removed from the channel end.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The shell is closed by a bonnet on the floating head side. The split-ring type also has the \u201cpull-through\u201d feature associated with the pull-through bundle type of floating head heat exchanger. It is recommended for high-pressure, non-hazardous process fluids.<\/span><\/p>\n<p><strong>Pros<\/strong><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High pressure is possible.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Differential expansion is provided by the floating head.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The shell and tube mechanical cleaning is possible.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The tube bundle is removable.<\/span><\/li>\n<\/ul>\n<p><strong>Cons<\/strong><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Failure of the gasket is not externally visible, therefore leakage might go undetected for some time.<\/span><\/li>\n<li aria-level=\"1\">\n<h4>Pull through bundle type (TypeT)<\/h4>\n<\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">In the pull-through bundle type, one of the tube sheets is designed to be small so that it may be pulled through the shell. This allows access to the inside of the shell so that it may be inspected, repaired, and cleaned. However, this design has fewer tubes than the others, which means that it transfers heat more slowly. There are fewer tubes to accommodate the bonnet flange and bolt circle.<\/span><\/p>\n<p><strong>Pros<\/strong><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The tube bundle is removable. (Also individual tubes)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Differential expansion is provided by the floating head.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Shell and tube side mechanical cleaning is possible.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Double tube sheets are possible.<\/span><\/li>\n<\/ul>\n<p><strong>Cons<\/strong><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The seal is not externally visible; therefore leakage might be undetected for some time.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">This type will tend to be more expensive than other types.<\/span><\/li>\n<li aria-level=\"1\">\n<h4>Outside packed Lantern ring type (Type W)<\/h4>\n<\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">In this type, the shell side and tube side streams are individually sealed by individual packing and are separated by a lantern ring. This is the lowest cost of the floating head designs. This type is recommended for low pressure, low temperature, and non-hazardous fluids.<\/span><\/p>\n<p><img decoding=\"async\" class=\"size-full wp-image-8769 aligncenter\" src=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/heat_exchangers_manufacturer_00001.jpg\" alt=\"What Is Floating Head Exchanger\" width=\"800\" height=\"600\" title=\"\" srcset=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/heat_exchangers_manufacturer_00001.jpg 800w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/heat_exchangers_manufacturer_00001-300x225.jpg 300w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/heat_exchangers_manufacturer_00001-768x576.jpg 768w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/heat_exchangers_manufacturer_00001-696x522.jpg 696w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/heat_exchangers_manufacturer_00001-560x420.jpg 560w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/heat_exchangers_manufacturer_00001-80x60.jpg 80w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/heat_exchangers_manufacturer_00001-160x120.jpg 160w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/heat_exchangers_manufacturer_00001-265x198.jpg 265w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><strong>Pros<\/strong><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The differential expansion between tubes is possible thru the floating head design, therefore eliminates the need for an expansion joint.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The tube bundle is removable. (Also individual tubes)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Tube side mechanical cleaning is possible.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Shell side mechanical cleaning is possible.<\/span><\/li>\n<\/ul>\n<p><strong>Cons<\/strong><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">A maximum of only two tube side passes is possible.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The shell and tube side leakage is possible.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Maximum temperatures of 375 degrees F and a maximum pressure of 300 psi limit the usage of these units at higher pressure and temperature.<\/span><\/li>\n<li aria-level=\"1\">\n<h4>Outside packed stuffing box type (Type P)<\/h4>\n<\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">In this type, a skirt attached to the floating tube sheet passes through the back end of the shell. The space between the skirt and the shell is sealed by several layers of packing and packing gland. Unlike the outside-packed lantern ring design, it includes four tubes and not two, making it faster at transferring heat from medium to medium. It is recommended for low pressure, low-temperature non-hazardous fluids.<\/span><\/p>\n<p><strong>Pros<\/strong><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High pressure on the tube side is possible.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The tube bundle is removable. (Also individual tubes)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Shell and tube mechanical cleaning is possible.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">More than two tube passes are possible to utilize the allowable pressure drop.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Packing failure is externally visible under operation.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">A double tube sheet is possible.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Differential expansion is provided by the packing.<\/span><\/li>\n<\/ul>\n<p><strong>Cons<\/strong><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Hazardous material should not be used on the shell side because of the possible leakage.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Packing will tend to limit shell fluids to temperatures below 300 degrees F and pressure below 150 psi.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">This type lacks positive sealing and thus is also prone to leakage.<\/span><\/li>\n<\/ul>\n<p><b>Advantages<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">No temperature limit between the two mediums<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Can operate under high temperature and high pressure, the average temperature is less than or equal to 450\u2103\uff0cand pressure is less than or equal to 6.4MPa.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Easy to clean and inspection<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High reliability and wide adaptability<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Suitable for the serious scaling occasion<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Suitable for the easy corrosion occasion<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Suitable for the dirty fluid application, due to ease of cleaning<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The tube bundle can be removed for inspection.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Possible mechanical cleaning of the outer surface of tubes<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Since tubes are straight, individual tubes can be replaced.\u00a0<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Expansion of tube and shell is not a problem<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The inside tube surface can be cleaned without removing the tube bundle.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">No limitation on the number of tube side passes<\/span><\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"size-full wp-image-8770 aligncenter\" src=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/2942a27f8325446da14fade973f988a0.jpg\" alt=\"What Is Floating Head Exchanger\" width=\"800\" height=\"450\" title=\"\" srcset=\"https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/2942a27f8325446da14fade973f988a0.jpg 800w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/2942a27f8325446da14fade973f988a0-300x169.jpg 300w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/2942a27f8325446da14fade973f988a0-768x432.jpg 768w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/2942a27f8325446da14fade973f988a0-696x392.jpg 696w, https:\/\/www.linquip.com\/blog\/wp-content\/uploads\/2021\/06\/2942a27f8325446da14fade973f988a0-747x420.jpg 747w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><b>Limitations<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">It is costly compared to the other heat exchangers<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">A large number of gasket joints<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Leakage may be a problem, unlike the U tube type heat exchanger due to the floating head.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Installed only horizontally<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Packing materials produce limits on design pressure and temperature.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Tubes cannot expand independently so that huge thermal shock applications should be avoided.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">To provide the floating-head cover it is necessary to bolt it to the tube sheet. The bolt circle requires the use of space where it would be possible to place a large number of tubes.<\/span><\/li>\n<\/ul>\n<p><b>Applications<\/b><\/p>\n<p><span style=\"font-weight: 400;\">This type of heat exchanger is widely used in different industries such as petrochemical plants and chemical industries. Some examples of this heat exchanger are as follow:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">General industrial applications requiring frequent cleaning<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Chemical processing applications for toxic fluids<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Hydrocarbon fluid condensers<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Special gas aftercoolers and intercoolers<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Air pollution control systems,\u00a0<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Secondary heat recovery solutions for returning heat to ovens, dryers, kilns,\u00a0<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Building heating\u00a0<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">OEM energy recovery applications<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">So, there you have every single fact to the question of <\/span><span style=\"font-weight: 400;\">what is floating head heat exchanger<\/span><span style=\"font-weight: 400;\">. If you enjoyed this article in Linquip, let us know by leaving a reply in the comment section. Is there any question we can help you through? Feel free to <a href=\"https:\/\/www.linquip.com\/sign-up?client_redirect=\/\">sign up<\/a> on our website to get the most professional advice from our experts.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Shell and tube exchangers are the most commonly used heat exchangers in process plants today. One of the main types of shell and tube heat exchangers is the floating head exchanger. This heat exchanger is unlike any shell and tube heat exchanger. It is one of the most used heat exchangers specially designed to be &#8230;<\/p>\n","protected":false},"author":6,"featured_media":8767,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"categories":[8,6],"tags":[],"class_list":["post-8766","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-heat-exchanger","category-hvac"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/posts\/8766","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/comments?post=8766"}],"version-history":[{"count":0,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/posts\/8766\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/media\/8767"}],"wp:attachment":[{"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/media?parent=8766"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/categories?post=8766"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.linquip.com\/blog\/wp-json\/wp\/v2\/tags?post=8766"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}